Get a demoSign inInstallation conditions | Outdoor erection | |
---|---|---|
Communication IF / Protocol | RS-422 (RS-485) / dedicated protocol (publicly available) | |
Maximum power consumption | About 190 VA | |
housing | Wiper: Remote control defroster / fan / heater: Automatic control | |
Waterproof structure | Compliant with JIS C 0920 anti-jet flow type | |
Wind speed | Normal operation | ~ 20 m / s (when using the wind receiver) |
Operable | ~ 40 m / s (manual operation, when using the wind receiver) | |
Non destructive | ~ 60 m / s | |
Paint color | Two tone of N 7 and N 4 (room temperature dry polyurethane paint) | |
Ambient temperature | -10 ° C to + 50 ° C (condition: energized, no frozen) | |
Ambient humidity | 30 to 90% RH (Relative Humidity, No Condensation) | |
Power supply | AC 100 V, 50 Hz / 60 Hz | |
External dimensions | W 480 x D 340 x H 362 mm ± 5 mm (excluding projections) | |
Mass | Approximately 17 kg | |
Factory option | Coating color, lens magnification, communication IF floodlight, cold district specification etc. ※ Request for consultation |
Swing range | Horizontal | 360 ° Endless |
---|---|---|
vertical | + 90 ° to -90 ° | |
Turning speed | Horizontal |
180 ° / s (at the maximum speed) |
vertical | 90 ° / s (at the maximum speed) | |
Stop precision | Horizontal vertical ± 0.15 or less | |
Number of stored presets | Up to 255 points |